Wednesday, 12 April 2017

The new 2017 Mitsubishi Heavy Industries Air Conditioning SCM-ZM-S Multi Inverter Heat Pump 240V~50Hz







All models have very high COP values, thanks to the application of the Inverter technology, which allows to vary the power supplied according to the cooling or heating demand. This allows to reach the set temperature more rapidly, and to keep it stable in time, with a saving of about 30% of energy consumption compared to the conventional fixed-speed air conditioners. The Twin Rotary compressor  outdoor units are characterized by low sound levels and moreover, all units operate in heating and cooling with a outdoor temperature limit of -15° C.



Technical Data


Model
SCM 60 ZM-S
SCM 80 ZM-S
SCM 100 ZM-S
SCM 125 ZM-S
Type
DC Inverter
DC Inverter
DC Inverter
DC Inverter
Connectable Indoor Units (MIN - MAX)
nb.
2 - 3
2 - 4
4* - 5
4* - 6
Connectable Total  Capacity  I.U.
kW
11.0
13.5
16.0
19.5
Nominal Capacity (T=35°C)
Cooling
kW
6.00 (1.80~7.50)
8.00 (1.80~9.20)
10.00 (1.80~12.00)
12.50 (1.80~14.00)
Nominal Power Input (T=35°C)
Cooling
kW
1.43 (0.50~2.39)
2.16 (0.48~2.83)
2.86 (0.65~4.03)
3.90 (0.65~4.80)
Annual  Energy  Consumption
Cooling
kWh/a
321
446
687
Energy Efficiency Class Seasonal
Cooling
626/20111
A++
A++
A
Energy Efficiency Class Seasonal Index
Cooling
SEER2
6.55
6.29
5.10
Coefficient of Rated Energy Efficiency
Cooling
EER3
4.20
3.70
3.50
3.21
Design load (Pdesignc)
Cooling
kW
6.00
8.00
10.00
Nominal Capacity (T=7°C)
Heating
kW
6.80 (1.50~7.80)
9.30 (1.50~9.80)
12.00 (1.50~13.50)
13.50 (1.50~14.00)
Nominal Power Input (T=7°C)
Heating
kW
1.51 (0.60~3.00)
2.26 (0.60~3.43)
2.93 (0.70~3.40)
3.25 (0.70~3.42)
Annual  Energy  Consumption
Heating
kWh/a
2480
2755
3519
Energy Efficiency Class Seasonal (average season)
Heating
626/20111
A+
A
A+
Energy Efficiency Class Seasonal Index (average season)
Heating
SCOP2
4.01
3.81
4.02
Coefficient of Rated Energy Efficiency
Heating
COP3
4.50
4.12
4.10
4.15
Design load (Pdesignh) @-10°C
Heating
kW
7.10
7.50
10.10
T° operational limit (Tol)
Heating
°C
-15
-15
-15
Power  supply
Ph-V-Hz
1-220~230V-50HZ
1-220~230V-50HZ
1-220~230V-50HZ
1-220~230V-50HZ
I.U. ~ O.U.
O.U.
O.U.
O.U.
O.U.
Input Rated Current (Cooling - Heating)
A
6.8 - 7.1
9.90 - 10.4
13.0 - 13.3
17.3 - 17.7
Wiring Cables I.U./ O.U. (without ground)
nb.
3 + 3 + 3
3 + 3 + 3 + 3
3 + 3 + 3 + 3 +3
3 + 3 + 3 + 3 + 3 + 3
Refrigerant Pipe Liquid side/Gas side
mm (inch.)
3x6.35 (1/4”)
3x9.52 (3/8”)
4x6.35 (1/4”)
4x9.52 (3/8”)
5x6.35 (1/4”)
5x9.52 (3/8”)
6x6.35 (1/4”)
6x9.52 (3/8”)
Max. splitting distance
m
40
70
90
90
Max. splitting level difference O.U./I.U. -  I.U/ O.U.
m
15/15
20/20
20/20
20/20
Refrigerant  Precharge
Kg
2.5
3.15
6
6
MAX. Splitting without Refrigerant Precharge
m
40
40
50
50
Additional Charge / Liquid Pipe ø1/4’
g/m
-
20
20
20
Temperature  range  cooling
°C
-15°C ~ +43°C
-15°C ~ +43°C
-15°C ~ +43°C
-15°C ~ +43°C
Temperature  range  heating
°C
-15°C ~ +24°C
-15°C ~ +24°C
-15°C ~ +24°C
-15°C ~ +24°C
Outdoor Unit
Dimensions (H*W*D)
mm
640x850(+65)x290
750x880(+73)x340
945x970(+73)x370
945x970(+73)x370
Net weight
Kg
49
62
92
92
Max. sound pressure level at 1 m
dB(A)
52
54
56
57
Max. sound power level
dB(A)
63
66
68
Max. air flow
m3/h
2520
3360
4500
4500






Contact Us:
10 Grisedale Court
Woburn Road Industrial Estate
Kempston
Bedfordshire
MK42 7EE
United Kingdom


Sales And Service:  +44 (0)1234 841221 
 

Tel:  +44 (0)845 567 7080        


Fax:  
+44 (0)1234 852662


SKYPE:  
ORIONAIRSALES
 

Saturday, 1 April 2017

Fujitsu Air Conditioning AOYG14LAC2 Multi-Split Inverter Heat Pump 2 x ASYG09LUCA (2.5Kw / 9000Btu) Wall Mounted 240V~50hZ

Includes:

1 x AOYG14LAC2 Inverter Heat Pump Condensing unit
2 x ASYG07LUCA Wall Mounted Air Conditioning  Heat Pump (2.0Kw / 7000 Btu)
2 x Wireless Controllers




Multiple indoor units can be connected to 1 outdoor unit, and long piping connection is also possible. Compared with single type, the outdoor unit can be installed in various places to realize the space-saving installation.

The AOYG Series Multi-split units make it easily possible to have combinations of different kinds of indoor units (wall, ducts, floor, cassette, etc.) with different capacities, in order to adapt to the strictest needs of the users. Furthermore, being fitted with Inverter technology allows greater performance and lower energy consumption. Thanks to the DC Multi Inverter system, the Fujitsu Multi-split Inverter units are up to 50% more efficient and offer a considerable energy saving with regard to the conventional models. The indoor units are distributed throughout the rooms of the home. This means the temperature reaches its optimum point in a rapid and uniform manner. In addition to more attractive aesthetics, the new design of the front of the units provides easier cleaning as the air return remains hidden at the top. The unit is a slim-line construction 330mm on small models.
Ideal For Home Applications

As there is no need to install a large number of outdoor units, the outside aesthetics of the home are virtually unaffected. Furthermore, these outdoor units offer great location flexibility to ease the installation of the indoor units enormously.

Product Key Feature's

CoP, up to 4.27
• Infra-red controller   
• Slim construction 330mm
• Pipe runs up to 30 metres
• Low noise – 21dBA on low
• Back-up switch for loss of controller
• Cold draft prevention on heat pump start up
• Fault diagnosis
• Auto re-start after power interruption
• PRE-CHARGED WITH REFRIGERANT for up to 30 metres pipe length
• With “Power Diffuser” effect for greater comfort.
• Automatic cleaning function.
• Cleaner and healthier air with ion generator incorporated in indoor unit.
• Low ambient tested to -10 Deg/C in heating.
• Light weight noise absorbing outdoor unit.



Indoor Unit:


Model No.
Indoor unit
ASYG07LUCA
ASYG09LUCA
ASYG12LUCA
ASYG14LUCA
kW Class
kW
2.0
2.5
3.5
4.0
Power Source
Single-phase, ~230V, 50Hz
Sound Pressure Level
Cooling
H/M/L/Q
dB(A)
35/30/28/21
36/32/28/21
37/34/31/21
41/36/33/25
Heating
35/30/28/21
36/32/28/21
37/34/31/21
41/36/34/27
Sound Power Level
Cooling
H
dB(A)
53
54
55
59
Heating
53
54
55
59
$LUÁRZ 5DWH
Cooling
H/M/L/Q
m3/h
570/520/470/330
600/550/470/330
660/600/530/330
710/640/570/390
Heating
570/520/470/330
600/550/470/330
660/600/530/330
710/640/590/430
Net Dimensions
mm
282×870×185
282×870×185
282×870×185
282×870×185
Weight
kg(lbs)
9.5 (21)
9.5 (21)
9.5 (21)
9.5 (21)
Connection Pipe Diameter
Liquid/Gas
Inches
1/4 / 3/8
1/4 / 3/8
1/4 / 3/8
1/4 / 1/2
List Price
£
377
403
468
539


Outdoor Unit: 


Outdoor
AOYG14LAC2

2 Way
AOYG18LAC2

2 Way
AOYG18LAT3

3 Way
AOYG24LAT3

3 Way
AOYG30LAT4

4 Way
Nominal Capacity (kW)
Cooling
4.00 (1.40-4.40)
5.00 (1.70-5.60)
5.40 (1.80-6.80)
6.80 (1.80-8.50)
8.00 (3.50-10.10)
Heating
4.40 (1.10-5.40)
5.60 (1.80-6.10)
6.80 (2.00-8.00)
8.00 (2.00-8.80)
9.60 (3.70-12.00)
Power Consumption (kW)
Cooling
1.09
1.56
1.35
1.94
2.22
Heating
1.03
1.41
1.62
2.00
2.40
EER / COP (Nominal Conditions)

3.67 / 4.27
3.21 / 3.97
4.00 / 4.20
3.51 / 4.00
3.60 / 4.00
Pdesign (kW) @ -10°C
Cooling
4.00
5.00
5.40
6.80
8.00
Heating
3.80
4.20
5.00
5.20
6.20
SEER
Cooling
6.70
6.60
6.90
6.40
6.20
SCOP
Heating (Average)
4.10
4.10
4.30
4.20
4.00
(QHUJ\ (IÀFLHQF\ &ODVV
Cooling
A++
A++
A++
A++
A++
Heating (Average)
A+
A+
A+
A+
A+
Annual Energy Consumption (kWh/a)
Cooling
209
265
274
372
451
Heating
1296
1434
1627
1730
2169
Dimensions (HxWxD) mm
Outer
540x790x290
540x790x290
700x900x330
700x900x330
830x900x330
Net Weight (kg)
Outer
37
38
55
55
68
Room Air Circulation (high) m3/h
Inner
1850
2050
3050
3300
3500
Outer
1850
2050
2750
3300
3300
Power Supply
V-PH-Hz
230 / 1 / 50
230 / 1 / 50
230 / 1 / 50
230 / 1 / 50
230 / 1 / 50
Power Supply To

Outdoor
Outdoor
Outdoor
Outdoor
Outdoor
Running Current (A)
Cooling
5.12
6.90
5.90
8.50
9.70
Heating
4.91
6.30
7.10
8.80
10.50
Starting Current
A
4.90
6.30
7.10
8.80
10.50
Suggested MCB/Fuse
A
16
16
16
16
20
Interconnecting Cable

3 + E
3 + E
3 + E
3 + E
3 + E
Sound Pressure (dB(A) Cooling)
Cooling
47
50
46
48
50
Heating
49
51
47
49
51
Sound Power (dB(A) Cooling)
Cooling
61
63
65
68
68
Heating
63
64
67
70
70
Max Pipe Length
m
30
30
50
50
70
Max Height Difference
m
15
15
15
15
15
Refrigerant Charge
m
20
20
30
30
50
Additional Refrigerant Charge
g/m
10
20
20
20
25
Pipe Size (inches)
Gas
3/8 x2
3/8 x2
3/8 x2 / 1/2 x1
3/8 x2 / 1/2 x1
3/8 x2 / 1/2 x2
Liquid
1/4 x2
1/4 x2
1/4 x3
1/4 x3
1/4 (6.35mm) x4
Operating Range (OC)
Cooling
10 ~ 46
10 ~ 46
-10 ~ 46
-10 ~ 46
0 ~ 46
Heating
-15 ~ 24
-15 ~ 24
-15 ~ 24
-15 ~ 24
-10 ~24
Refrigerant

R410A
R410A
R410A
R410A
R410A
List Price
£
904
1092
1233
1406
1919


PDF Data Sheet: