1 x AOYG14LAC2 Inverter Heat Pump Condensing unit
2 x ASYG07LUCA Wall Mounted Air Conditioning Heat Pump (2.0Kw / 7000 Btu)
2 x Wireless Controllers
Multiple indoor units can be connected to 1 outdoor unit, and long piping connection is also possible. Compared with single type, the outdoor unit can be installed in various places to realize the space-saving installation.
The AOYG Series Multi-split units make it easily possible to have combinations of different kinds of indoor units (wall, ducts, floor, cassette, etc.) with different capacities, in order to adapt to the strictest needs of the users. Furthermore, being fitted with Inverter technology allows greater performance and lower energy consumption. Thanks to the DC Multi Inverter system, the Fujitsu Multi-split Inverter units are up to 50% more efficient and offer a considerable energy saving with regard to the conventional models. The indoor units are distributed throughout the rooms of the home. This means the temperature reaches its optimum point in a rapid and uniform manner. In addition to more attractive aesthetics, the new design of the front of the units provides easier cleaning as the air return remains hidden at the top. The unit is a slim-line construction 330mm on small models.
Ideal For Home Applications
As there is no need to install a large number of outdoor units, the outside aesthetics of the home are virtually unaffected. Furthermore, these outdoor units offer great location flexibility to ease the installation of the indoor units enormously.
As there is no need to install a large number of outdoor units, the outside aesthetics of the home are virtually unaffected. Furthermore, these outdoor units offer great location flexibility to ease the installation of the indoor units enormously.
Product Key Feature's
• CoP, up to 4.27
• Infra-red controller
• Slim construction 330mm
• Pipe runs up to 30 metres
• Low noise – 21dBA on low
• Back-up switch for loss of controller
• Cold draft prevention on heat pump start up
• Fault diagnosis
• Auto re-start after power interruption
• PRE-CHARGED WITH REFRIGERANT for up to 30 metres pipe length
• With “Power Diffuser” effect for greater comfort.
• Automatic cleaning function.
• Cleaner and healthier air with ion generator incorporated in indoor unit.
• Low ambient tested to -10 Deg/C in heating.
• Light weight noise absorbing outdoor unit.
Indoor Unit:
Model No.
|
Indoor unit
|
ASYG07LUCA
|
ASYG09LUCA
|
ASYG12LUCA
|
ASYG14LUCA
| ||
kW Class
|
kW
|
2.0
|
2.5
|
3.5
|
4.0
| ||
Power Source
|
Single-phase, ~230V, 50Hz
| ||||||
Sound Pressure Level
|
Cooling
|
H/M/L/Q
|
dB(A)
|
35/30/28/21
|
36/32/28/21
|
37/34/31/21
|
41/36/33/25
|
Heating
|
35/30/28/21
|
36/32/28/21
|
37/34/31/21
|
41/36/34/27
| |||
Sound Power Level
|
Cooling
|
H
|
dB(A)
|
53
|
54
|
55
|
59
|
Heating
|
53
|
54
|
55
|
59
| |||
$LUÁRZ 5DWH
|
Cooling
|
H/M/L/Q
|
m3/h
|
570/520/470/330
|
600/550/470/330
|
660/600/530/330
|
710/640/570/390
|
Heating
|
570/520/470/330
|
600/550/470/330
|
660/600/530/330
|
710/640/590/430
| |||
Net Dimensions
|
mm
|
282×870×185
|
282×870×185
|
282×870×185
|
282×870×185
| ||
Weight
|
kg(lbs)
|
9.5 (21)
|
9.5 (21)
|
9.5 (21)
|
9.5 (21)
| ||
Connection Pipe Diameter
|
Liquid/Gas
|
Inches
|
1/4 / 3/8
|
1/4 / 3/8
|
1/4 / 3/8
|
1/4 / 1/2
| |
List Price
|
£
|
377
|
403
|
468
|
539
|
Outdoor Unit:
Outdoor
|
AOYG14LAC2
2 Way |
AOYG18LAC2
2 Way |
AOYG18LAT3
3 Way |
AOYG24LAT3
3 Way |
AOYG30LAT4
4 Way | |
Nominal Capacity (kW)
|
Cooling
|
4.00 (1.40-4.40)
|
5.00 (1.70-5.60)
|
5.40 (1.80-6.80)
|
6.80 (1.80-8.50)
|
8.00 (3.50-10.10)
|
Heating
|
4.40 (1.10-5.40)
|
5.60 (1.80-6.10)
|
6.80 (2.00-8.00)
|
8.00 (2.00-8.80)
|
9.60 (3.70-12.00)
| |
Power Consumption (kW)
|
Cooling
|
1.09
|
1.56
|
1.35
|
1.94
|
2.22
|
Heating
|
1.03
|
1.41
|
1.62
|
2.00
|
2.40
| |
EER / COP (Nominal Conditions)
|
3.67 / 4.27
|
3.21 / 3.97
|
4.00 / 4.20
|
3.51 / 4.00
|
3.60 / 4.00
| |
Pdesign (kW) @ -10°C
|
Cooling
|
4.00
|
5.00
|
5.40
|
6.80
|
8.00
|
Heating
|
3.80
|
4.20
|
5.00
|
5.20
|
6.20
| |
SEER
|
Cooling
|
6.70
|
6.60
|
6.90
|
6.40
|
6.20
|
SCOP
|
Heating (Average)
|
4.10
|
4.10
|
4.30
|
4.20
|
4.00
|
(QHUJ\ (IÀFLHQF\ &ODVV
|
Cooling
|
A++
|
A++
|
A++
|
A++
|
A++
|
Heating (Average)
|
A+
|
A+
|
A+
|
A+
|
A+
| |
Annual Energy Consumption (kWh/a)
|
Cooling
|
209
|
265
|
274
|
372
|
451
|
Heating
|
1296
|
1434
|
1627
|
1730
|
2169
| |
Dimensions (HxWxD) mm
|
Outer
|
540x790x290
|
540x790x290
|
700x900x330
|
700x900x330
|
830x900x330
|
Net Weight (kg)
|
Outer
|
37
|
38
|
55
|
55
|
68
|
Room Air Circulation (high) m3/h
|
Inner
|
1850
|
2050
|
3050
|
3300
|
3500
|
Outer
|
1850
|
2050
|
2750
|
3300
|
3300
| |
Power Supply
|
V-PH-Hz
|
230 / 1 / 50
|
230 / 1 / 50
|
230 / 1 / 50
|
230 / 1 / 50
|
230 / 1 / 50
|
Power Supply To
|
Outdoor
|
Outdoor
|
Outdoor
|
Outdoor
|
Outdoor
| |
Running Current (A)
|
Cooling
|
5.12
|
6.90
|
5.90
|
8.50
|
9.70
|
Heating
|
4.91
|
6.30
|
7.10
|
8.80
|
10.50
| |
Starting Current
|
A
|
4.90
|
6.30
|
7.10
|
8.80
|
10.50
|
Suggested MCB/Fuse
|
A
|
16
|
16
|
16
|
16
|
20
|
Interconnecting Cable
|
3 + E
|
3 + E
|
3 + E
|
3 + E
|
3 + E
| |
Sound Pressure (dB(A) Cooling)
|
Cooling
|
47
|
50
|
46
|
48
|
50
|
Heating
|
49
|
51
|
47
|
49
|
51
| |
Sound Power (dB(A) Cooling)
|
Cooling
|
61
|
63
|
65
|
68
|
68
|
Heating
|
63
|
64
|
67
|
70
|
70
| |
Max Pipe Length
|
m
|
30
|
30
|
50
|
50
|
70
|
Max Height Difference
|
m
|
15
|
15
|
15
|
15
|
15
|
Refrigerant Charge
|
m
|
20
|
20
|
30
|
30
|
50
|
Additional Refrigerant Charge
|
g/m
|
10
|
20
|
20
|
20
|
25
|
Pipe Size (inches)
|
Gas
|
3/8 x2
|
3/8 x2
|
3/8 x2 / 1/2 x1
|
3/8 x2 / 1/2 x1
|
3/8 x2 / 1/2 x2
|
Liquid
|
1/4 x2
|
1/4 x2
|
1/4 x3
|
1/4 x3
|
1/4 (6.35mm) x4
| |
Operating Range (OC)
|
Cooling
|
10 ~ 46
|
10 ~ 46
|
-10 ~ 46
|
-10 ~ 46
|
0 ~ 46
|
Heating
|
-15 ~ 24
|
-15 ~ 24
|
-15 ~ 24
|
-15 ~ 24
|
-10 ~24
| |
Refrigerant
|
R410A
|
R410A
|
R410A
|
R410A
|
R410A
| |
List Price
|
£
|
904
|
1092
|
1233
|
1406
|
1919
|
PDF Data Sheet: