Thursday 12 July 2018

Mitsubishi Electric Air Conditioning R32 MSZ-F Multi Inverter Outdoor Unit 240v 50Hz

A++/A+++ Rated energy product    





The R32 MXS-F outdoor multi-split system allows up to four M Series or Mr Slim wall mounted, cassette, ducted or ceiling suspended indoor units of different capacities to be operated from a single outdoor unit. This makes it an economic and efficient answer for multi-room applications, whilst also offering space saving benefits. Up to four indoor units may be connected to a single outdoor unit Energy saving inverter controlled outdoor unit adjusts compressor performance to economically match the demand for heating and cooling Units may be added within the capacity of the system as requirements change Capacities of indoor units may be mixed to suit individual rooms.

Key product Feature's:
 

 
  • Multiple indoor units connected to a single outdoor unit
  • Single outdoor unit for minimal noise and space impact
  • Energy saving inverter controlled performance A+++
  • Compact design R32 outdoor unit
  • Mixture of different types of indoor unit
  • High SCOP
  • Auto re-start after power interruption
  • PRE-CHARGED WITH R32 REFRIGERANT
  • Fault diagnosis
MXZ-F R32 Outdoor Units:
 
MXZ-F - OUTDOOR UNITS
MXZ-2F33VF
MXZ-2F42VF
MXZ-3F54VF
MXZ-3F68VF
MXZ-4F72VF
NUMBER OF CONNECTABLE INDOOR UNITS
2
2
2 - 3
2 - 3
2 - 4
CAPACITy (kW)                       Heating (nominal)
4.0 (1.0-4.1)
4.5 (1.0-4.8)
7.0 (2.6-9.0)
8.6 (2.6-10.6)
8.6 (3.4-10.7)
Cooling (nominal)
3.3 (1.1-3.8)
4.2 (1.1-4.4)
5.4 (2.9-6.8)
6.8 (2.9-8.4)
7.2 (3.7-8.8)
Heating (UK)
3.32 (0.83-3.40)
3.74 (0.84-3.99)
5.81 (2.16-7.47)
7.14 (2.16-8.80)
7.14 (2.82-8.89)
Cooling (UK)
3.23 (1.07-3.72)
4.12 (1.08-4.32)
5.3 (2.85-6.67)
6.66 (2.84-8.23)
7.0 (3.59-8.56)
COP / EER (nominal)*1
4.40 / 3.90
5.10 / 4.30
4.60 / 4.10
4.50 / 3.70
4.60 / 3.90
SCOP / SEER (BSEN14825)
4.16 / 6.13
4.60 / 8.69
4.61 / 8.52
4.12 / 7.96
4.07 / 8.13
ErP ENERGy EFFICIENCy CLASS   Heating/Cooling
A+ / A++
A++ / A+++
A++ / A+++
A+ / A++
A+ / A++
MAX AIRFLOW (m3/min)      Heating/Cooling
33.7 / 32.9
33.3 / 27.7
43.0 / 42.1
43.0 / 42.1
43.0 / 42.1
SOUND PRESSURE LEVEL (dBA)    Heating/Cooling
50 / 49
50 / 44
50 / 46
53 / 48
54 / 48
SOUND POWER LEVEL (dBA)    Cooling
60
59
59
63
63
DIMENSIONS (mm)              Width x Depth x Height
800 x 285 x 550
800 x 285 x 550
840 x 330 x 710
840 x 330 x 710
840 x 330 x 710
WEIGHT (kg)
33
37
58
58
59
ELECTRICAL SUPPLy
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
PHASE
Single
Single
Single
Single
Single
POWER INPUT (kW)                   Heating/Cooling (nominal)
0.909 / 0.846
0.88 / 0.98
1.52 / 1.32
1.91 / 1.84
1.87 / 1.85
Heating/Cooling (UK)
0.82 / 0.68
0.90 / 0.78
1.38 / 1.06
1.73 / 1.47
1.69 / 1.48
STARTING CURRENT (A)
4.6
4.2
7.0
10.5
10.0
RUNNING CURRENT (A)     Heating/Cooling [MAX]
4.6 / 4.3 [10.0]
4.2 / 4.5 [12.2]
7.0 / 5.9 [18.0]
10.5 / 9.6 [18.0]
10.0 / 9.5 [18.0]
INTERCONNECTING CABLE No. CORES
4 Core
4 Core
4 Core
4 Core
4 Core
TOTAL PIPE LENGTH (m)
20
30
50
60
60
MAX PIPE LENGTH PER INDOOR UNIT (m)
15
20
25
25
25
MAX HEIGHT DIFFERENCE (m)
10
15 (10 if OU higher than IU)
15 (10 if OU higher than IU)
15 (10 if OU higher than IU)
15 (10 if OU higher than IU)
CHARGE REFRIGERANT (kg) /
CO2 EQUIVALENT (t) - R32 (GWP 675)
1.00 / 0.68 (20m)
1.20 / 0.81 (20m)
1.40 / 0.95 (50m)
1.40 / 0.95 (60m)
1.40 / 0.95 (60m)
MAX ADDITIONAL REFRIGERANT (kg) /
CO2 EQUIVALENT (t) - R32 (GWP 675)
1.00 / 0.68
1.40 / 0.95
2.40 / 1.62
2.40 / 1.62
2.40 / 1.62
FUSE RATING (BS88) - HRC (A)
16
16
25
25
25

 


PDF Data:




No comments:

Post a Comment