Full List Of Samsung Air Conditioning Error Codes

Full List Of Samsung Air Conditioning Error Codes 




 Code
Explanation & Check Points












Ch
Compressor Starting Delay - Crankcase heater initiated



"P0"
System down due to high temperature discharge sensor


"P1"
System down due to the high temperature of condenser



"P2"
Sump Comp Down


"P3"
System down due to the lower temperature switch detection



"P4"
System Start down due to reverse phase of the 3 phase


"P5"
System down due to frozen heat exchanger




"P6"
Error of momentary power failure (dissapears when unit is off/on)


"P7"
Compressor down due to protection control of high pressure sensor


"P8"
Compressor down due to protection control of low pressure sensor


"P9"
Problem removing frost





"PA"
Compressor down due to protection control of condensation ratio





"t1"
Error of OUT TEMP sensor (OPEN/SHORT)




"t2"
Error of COND TEMP sensor (Open/short)


"t3"
Error of PWM Discharge TEMP sensor (Open/Short)




"t4"
Error of liquid refrigerant pipe (cond out) Temp (Open/short)


"t5"
Error of OIL TEMP sensor (Open/Short)




"t6"
Error of Suction temp sensor (Open/Short)


"t7"
Error of high pressure sensor (Open/Short)




"t8"
Error of low pressure sensor (Open/Short)


"t9"
Error of fixed compressor discharge sensor (Open/Short)






"E1"
System down due to the communication error after completion of tracking

"E2"
Mismatching of the numbers of set indoor units to actual indoor units


"E3"
Indoor Unit float switch error




"E5"
Setting error of option switch in indoor unit





"Ax"
Indoor Unit EVAP IN sensor breakaway




"bx"
Indoor Unit EVAP Out Sensor breakaway


"Cx"
Electronic expansion valve open error




"dx"
Electronic expansion valve close error


"fx"
Simultaneous breakaway of indoor unit EVAP IN and EVAP OUT sensor





"G2"
Total Leakage of Refrigerant in outdoor unit/Loading Failure



"G3"
Breakaway of COND MID sensor in outdoor unit


"G6"
Breakaway of OIL temperature sensor (Detected once or more times)


"G7"
Breakaway of suction sensor


"GC"
Breakaway of load compressor discharge sensor







"9x"
OPEN/SHORT error of room sensor in indoor unit




"rx"
OPEN/SHORT of EVAP IN sensor in indoor unit


"yx"
OPEN/SHORT of EVAP OUT sensor in indoor unit




"ux"
Error of fan setting





"tU"
Outdoor temperature being below -5 Deg. C when cooling mode


"to"
Outdoor temperature being over 30 Deg. C when in heating mode





E101
Communication Error between the indoor unit and the Panel



E121


E122




E123


E128




E129


E130
Simultaneous breakaway of indoor unit EVAP IN/OUT Sensor



E131
Auxiliary (electric) heater sensor 1 error


E132
Auxiliary (electric) heater sensor 2 error




E133
Auxiliary (electric) heater sensor 3 error


E134
Shutter sensor error





E135
Perfect fan sensor Error


E140
MCU temp. sensor open/short




E151


E152





E153


E154





E161
Mixed Operation error (operate heat & cool mode at same time)


E162
EPROM Error





E163
Option setting error


E165
Electric heater discharge temperature protect error




E166
No fan error related to the electric heater


E167
S/W setup error in peripheral control device using option



E180


E181


E182
The 2nd MCU SOL V/V error


E190
There is no change of EVAP in temperature during the piping check


E191
There is no change of EVAP OUT temperature during the piping check


E192
EVAP IN temperature error during the piping check




E193
EVAP OUT temperature error during the piping check


E201




E202


E203


E210


E211



E212


E213



E214



E215
Indoor unit address in MCU error




E216
DIP switch for indoor unit setting in MCU set ON error

E217
Dip switch for indoor unit setting in MC set OFF error


E221
OUT-TEMP sensor OPEN/SHORT sensor error

E226
Out-Temp sensor breakaway





E231
COND-OUT MAIN TEMP sensor error OPEN/SHORT

E236
COND-OUT MAIN TEMP sensor error OPEN/SHORT



E241
COND-MID sensor breakaway of outdoor unit

E246
COND-OUT 1 breakaway





E251
PWM DISCHARGE TEMP sensor error OPEN/SHORT

E256
Fixed capacity compressor 1 DCHRG sensor error OPEN/SHORT

E257
Fixed capacity compressor 2 DCHRG sensor error OPEN/SHORT

E258
Fixed capacity compressor 3 DCHRG sensor error OPEN/SHORT

E261
Digital discharge sensor breakaway

E262
Fixed 1 discharge sensor breakaway




E263
Fixed 2 discharge sensor breakaway

E264
Fixed 3 discharge sensor breakaway




E265
Sump-main breakaway error

E266
Sump Sub 1 breakaway error





E267
Sump Sub 2 breakaway error

E268
Sump Sub 3 breakaway error





E269
Suction breakaway error

E271
SUMP TEMP DIGITAL sensor error OPEN/SHORT



E276
SUMP TEMP FIXED 1 sensor error OPEN/SHORT

E277
SUMP TEMP FIXED 2 sensor error OPEN/SHORT



E278
SUMP TEMP FIXED 3 sensor error OPEN/SHORT

E291
High pressure sensor error OPEN/SHORT




E296
Low pressure sensor error OPEN/SHORT

E301
High Pressure Sensor Breakaway




E306
Low Pressure Sensor Breakaway

E308
Suction Temp. Sensor ERROR (OPEN/SHORT)



E312
Main Cooling sol. v/v open error

E313
4-Way v/v operation error







E401
Outdoor unit freezing detection 1




E402
Outdoor unit freezing detection 2

E403
Outdoor unit freezing detection 3 - freezing COMP DOWN


E404
Outdoor unit overload 1 protection control error

E405
Outdoor unit overload 2 protection control error



E406
Outdoor unit overload 3 protection control error

E407
Compressor down by high pressire sensor protection control 1

E408
Compressor down by high pressire sensor protection control 2

E409
Compressor down by high pressire sensor protection control 3

E410
Compressor down by low pressure sensor protection control 1

E411
Compressor down by low pressure sensor protection control 2

E412
Compressor down by low pressure sensor protection control 3

E413
Outdoor unit SUMP DOWN 1 protection control



E414
Outdoor unit SUMP DOWN 2 protection control

E415
Outdoor unit SUMP DOWN 3 protection control



E416
Outdoor unit discharge temperature 1 protection control

E417
Outdoor unit discharge temperature 2 protection control


E418
Outdoor unit discharge temperature 3 protection control

E419
Outdoor unit EEV open 1 self diagnosis error



E420
Outdoor unit EEV open 2 self diagnosis error

E421
Outdoor unit EEV open 3 self diagnosis error



E422
Outdoor unit EEV close 1 self diagnosis error

E423
Outdoor unit EEV close 2 self diagnosis error



E424
Outdoor unit EEV close 3 self diagnosis error

E425
Outdoor unit reverse phase detection 1 error



E426
Outdoor unit reverse phase detection 2 error

E427
Outdoor unit reverse phase detection 3 error



E428
Outdoor unit compression rate 1 error

E429
Outdoor unit compression rate 2 error




E430
Outdoor unit compression rate 3 error

E440
Forbid heating mode operation when outdoor temperature over 30 Deg. C
E441
Forbid cooling mode operation when outdoor temperature below -5 Deg. C
E442
Refrigerant charding error in the heating mode



E452
Instant Power off (dissapear when compresson run)



E551
Defrosting operation





E552
Low Discharge Pressure

E553
Eqability Operation






E554
Loading Failure Full leakage of refrigerant of outdoor unit



E601
Communication error between wired remote controller and indoor unit

E602
Communication error between master and slave wired remote controller
E603
Communication error between 7 day scheduler and wired remote controller


E701
Float S/W detection error





E702
Indoor unit EEV closing error

E703
Indoor unit EEV opening error





E704
MCU Sol v/v failure