Mitsubishi Heavy Industries Air to Water Heat Pump is a complete modern system for heating, cooling and producing hot sanitary water for small houses, offering effective energy saving and reducing carbon dioxide emission. Safe and economical with integrated hot water heater, immersion heater, circulating pump and climate system within the indoor unit.
The heat energy is retrieved from the outdoor air through an outdoor unit (FDCW100VNX), and is transferred to the indoor unit (HM270V) by the medium of refrigerant circulated in closed piping system. This eliminates the needs of bore holes and coils in the ground for conventional systems.
Optimum annual operation costs thanks to the inverter driven compressor. The speed of the compressor is controlled according to the demand, and the industry’s highest COP level of 3.70 in heating operation has been achieved.
The compact size (600x650mm footprint) has been achieved by integrating the hot water tank for sanitary water together with the water heat exchanger in the indoor unit. Electric wiring and piping works are simpler due to integrated indoor unit design.
Max temperature flow line is 65°C with use of a large-capacity auxiliary electric heater as standard equipment for back-up, so that the system will be able to cope with irregular and excessive use of hot water. (58°C with only use of compressor). Various sterilization temperature settings are available according to the requirements of each country.
Key Product Feature's:
- Model: FDCW100VNX
- Nominal Heating - 9.0 (3.5~12.0) kW
- Nominal Cooling - 8.0 (3.0~9.0) kW
- COP Heating - 3.75
- 240Volt 1 phase (also available in 3phase)
- Refrigerant R417A / R410A
- Option of solar collector connection
- Rated to -20DegC Heating
- Dimensions: L1760, W600, D650
- Heating and cooling
- Weight 214Kg ( indoor and outdoor)
Heating
|
| |
Nominal Capacity (min~max) | 9.0 (3.5~12.0) kW | |
COP (Nominal) | 3.70 | |
Tapping Capacity (Sanitary hot water) in:15°C | out:40°C | 270 liter 12 liter/min
200 liter 16 liter/min |
Tapping Capacity (Sanitary hot water) in:15°C | out:40°C |
Cooling |
| |
Nominal Capacity (min~max) | 8.0 (3.0~9.0) | |
COP (Nominal) | 2.87 | |
Technical Data |
| |
Working range during heating with compressor (ambient temperature) | -20 - +43°C | |
Working range during cooling (ambient temperature) |
| +15 - +43°C |
Max temperature flow line | 65°C | |
Max temperature flow line, only use of compressor |
| 58°C |
Refrigerant quantity (R410A) | 2.9 kg | |
Max length, refrigerant pipe |
| 12 m |
Max height difference, refrigerant pipe
| 7 m
| |
Dimensions, refrigerant pipe
|
| Gas pipe : OD15.88 (5/8") Liquid pipe : OD9.52 (3/8") |
Pipe connections (outdoor to indoor) |
| Flare |
HM270V (Indoor unit) |
| ||
Immersion heater | Max 9 kW | ||
Volume, total |
| 270 litre | 5%+ - |
Volume, hot water coil | 14 litre | ||
Height
|
| 1760 mm (+20-50 mm, adjustable feet) | |
Width | 600 mm | ||
Depth |
| 650 mm | |
Weight (without water in tank) | 140 kg | ||
Electrical connections |
| 1Phase 230V / 3Phase 400V 50Hz | |
FDCW100VNX (Outdoor unit) |
| ||
Height | 845 mm | ||
Width |
| 970 mm | |
Depth | 370 mm (+80 mm with foot rail) | ||
Weight |
| 74 kg |