Wall Mounted Single Systems ASY, ASYA & ASYB Includes AWYZ Nokria Models
Red Light Operation
|
Green Light Timer
|
Current Models
|
Off
|
2 Flashes
|
Reverse Comms Fail at Startup
|
Off
|
3 Flashes
|
Reverse Comms Fail In Use
|
Off
|
4 Flashes
|
Forward Comms Fail at Startup
|
Off
|
5 Flashes
|
Forward
Comms Fail In
Use
|
Off
|
8 Flashes
|
Wired Remote Control Failure
|
2 Flashes
|
2 Flashes
|
Indoor Air Sensor Fail
|
2 Flashes
|
3 Flashes
|
Indoor Pipe Sensor Fail
|
2 Flashes
|
4 Flashes
|
Indoor heat exchanger sensor error
|
2 Flashes
|
6 Flashes
|
Float switch operated
|
3 Flashes
|
2 Flashes
|
OD Disch Sensor Fail
|
3 Flashes
|
3 Flashes
|
OD Pipe Sensor Fail
|
3 Flashes
|
4 Flashes
|
OD Air Sensor
Fail
|
3 Flashes
|
7 Flashes
|
Heatsink
Sensor Error
|
3 Flashes
|
8 Flashes
|
Compressor Temp Sensor Fail
|
4 Flashes
|
2 Flashes
|
Forced Auto Switch Welded
|
4 Flashes
|
3 Flashes
|
Main Relay Welded
|
4 Flashes
|
4 Flashes
|
Power Failure
|
4 Flashes
|
7 Flashes
|
VDD Permament Stop Protection
|
4 Flashes
|
8 Flashes
|
Reverse VDD Permament Stop
|
5 Flashes
|
2 Flashes
|
IPM Protection
|
5 Flashes
|
3 Flashes
|
CT Abnormal
|
5 Flashes
|
5 Flashes
|
Compressor Failure
|
5 Flashes
|
6 Flashes
|
Outdoor Fan Failure
|
6 Flashes
|
2 Flashes
|
ID Fan Motor
Locked
|
6 Flashes
|
3 Flashes
|
ID Fan Motor Rotation Error
|
7 Flashes
|
2 Flashes
|
High Discharge Temperature
|
7 Flashes
|
3 Flashes
|
High Pressure
|
7 Flashes
|
4 Flashes
|
4-Way valve
abnormal
|
7 Flashes
|
5 Flashes
|
Pressure Switch Fail
|
7 Flashes
|
6 Flashes
|
Compressor Temperature error
|
8 Flashes
|
2 Flashes
|
Active Filter AFM Fail 1st Time
|
8 Flashes
|
3 Flashes
|
Active Filter AFM Fail 2nd Time
|
8 Flashes
|
4 Flashes
|
PFC Circuit Error
|
Blinking
|
Blinking
|
PCB Failure
|
Contact Us With Your Spares Inquiry Below:
Call: +44(0)845 567 7080
E-mail: Info@orionair.co.uk
|
No comments: