Wednesday 12 August 2015

Fujistu Air Conditioning Fault Codes for Wall Mounted Single Systems ASY, ASYA & ASYB Includes AWYZ Nokria Models



Wall Mounted Single Systems ASY, ASYA & ASYB Includes AWYZ Nokria Models





Red Light Operation
Green Light Timer
Current Models
Off
2 Flashes
Reverse Comms Fail at Startup
Off
3 Flashes
Reverse Comms Fail In Use
Off
4 Flashes
Forward Comms Fail at Startup
Off
5 Flashes
Forward Comms Fail In Use
Off
8 Flashes
Wired Remote Control Failure
2 Flashes
2 Flashes
Indoor Air Sensor Fail
2 Flashes
3 Flashes
Indoor Pipe Sensor Fail
2 Flashes
4 Flashes
Indoor heat exchanger sensor error
2 Flashes
6 Flashes
Float switch operated
3 Flashes
2 Flashes
OD Disch Sensor Fail
3 Flashes
3 Flashes
OD Pipe Sensor Fail
3 Flashes
4 Flashes
OD Air Sensor Fail
3 Flashes
7 Flashes
Heatsink Sensor Error
3 Flashes
8 Flashes
Compressor Temp Sensor Fail
4 Flashes
2 Flashes
Forced Auto Switch Welded
4 Flashes
3 Flashes
Main Relay Welded
4 Flashes
4 Flashes
Power Failure
4 Flashes
7 Flashes
VDD Permament Stop Protection
4 Flashes
8 Flashes
Reverse VDD Permament Stop
5 Flashes
2 Flashes
IPM Protection
5 Flashes
3 Flashes
CT Abnormal
5 Flashes
5 Flashes
Compressor Failure
5 Flashes
6 Flashes
Outdoor Fan Failure
6 Flashes
2 Flashes
ID Fan Motor Locked
6 Flashes
3 Flashes
ID Fan Motor Rotation Error
7 Flashes
2 Flashes
High Discharge Temperature
7 Flashes
3 Flashes
High Pressure
7 Flashes
4 Flashes
4-Way valve abnormal
7 Flashes
5 Flashes
Pressure Switch Fail
7 Flashes
6 Flashes
Compressor Temperature error
8 Flashes
2 Flashes
Active Filter AFM Fail 1st Time
8 Flashes
3 Flashes
Active Filter AFM Fail 2nd Time
8 Flashes
4 Flashes
PFC Circuit Error
Blinking
Blinking
PCB Failure



Contact Us With Your Spares Inquiry Below:


Call: +44(0)845 567 7080

E-mail: Info@orionair.co.uk 









No comments:

Post a Comment