Fujistu Air Conditioning Fault Codes For wireless indoor units AUY, ABY and AWY Models. Including Multi Systems (Not J Series or VRF)
Red Light Operation
|
Green Light Timer
|
Yellow Light Swing
|
|
On
|
|
|
Normal
|
On
|
Slow Blink
|
Slow Blink
|
Test
|
Blinks
|
Blinks
|
Off
|
ID PCB Fail
|
Blinks
|
Blinks
|
Blinks
|
OD PCB Fail
|
Blinks
|
2 Pulses
|
Off
|
OD Power Connection Failure
|
Blinks
|
3 Pulses
|
Off
|
OD Unit Pipe Sensor Fail
|
Blinks
|
4 Pulses
|
Off
|
OD Unit Air Sensor Fail
|
Blinks
|
4 Pulses
|
Blinks
|
OD Unit Air Sensor Short
|
Blinks
|
5 Pulses
|
Off
|
OD Unit Discharge Sensor Fail
|
Blinks
|
5 Pulses
|
Blinks
|
OD Unit Discharge Sensor Short
|
Blinks
|
6 Pulses
|
Off
|
High Pressure
|
Blinks
|
7 Pulses
|
Off
|
High Discharge or Compressor Temp
|
Blinks
|
9 Pulses
|
Off
|
OD Unit Compressor Temp Sensor
|
Blinks
|
10 Pulses
|
Off
|
IPM Error
|
Blinks
|
11 Pulses
|
Off
|
CT Error
|
Blinks
|
12 Pulses
|
Off
|
AFM Filter Error
|
Blinks
|
13 Pulses
|
Off
|
Compressor Error
|
Blinks
|
14 Pulses
|
Off
|
OD Fan Motor Fail
|
2 Pulses
|
Blinks
|
Off
|
Air Sensor Open
|
2 Pulses
|
Blinks
|
Blinks
|
Air Sensor Closed
|
3 Pulses
|
Blinks
|
Off
|
Pipe Sensor Open
|
3 Pulses
|
Blinks
|
Blinks
|
Pipe Sensor Closed
|
4 Pulses
|
Blinks
|
Off
|
Drain Problem
|
5 Pulses
|
Blinks
|
Off
|
Communication Error
|
5 Pulses
|
Blinks
|
Blinks
|
OD PCB or Wiring Error
|
6 Pulses
|
Blinks
|
Off
|
Indoor Fan Failure
|
Contact Us With Your Spares Inquiry Below:
Call: +44(0)845 567 7080
E-mail: Info@orionair.co.uk
|
No comments:
Post a Comment