Friday 14 May 2021

Fujitsu air conditioning unit selector and fault codes 2021

 










Fujitsu Fault Codes:




Error Detail

Indoor LED Display Flashes

Wired RC

Operation

Timer

Economy

Serial communication error

1

1

Continuous

11

Wired RC communication error

1

2

Continuous

12

Network communication error

1

4

Continuous

14

Check run unfinished

1

5

Continuous

15

Transmission/Peripheral connect error

1

6

Continuous

16

Refrigeration circuit address setting error

2

1

Continuous

21

Indoor unit capacity error

2

2

Continuous

22

Combination error

2

3

Continuous

23

Connection unit number error

2

4

Continuous

24

Address setting error

2

6

Continuous

26

Master/Slave unit set-up error

2

7

Continuous

27

Connection unit number error in WRC circuit

2

9

Continuous

29

Power supply interruption error

3

1

Continuous

31

Indoor PCB EPPROM error

3

2

Continuous

32

Manual auto switch error

3

5

Continuous

35

Indoor unit WRC communication error

3

10

Continuous

3A

Inlet air temp sensor error

4

1

Continuous

41

Indoor Heat-Ex middle temp sensor error

4

2

Continuous

42

Indoor unit fan motor error

5

1

Continuous

51

Indoor EEV error

5

2

Continuous

52

Drain pump error

5

3

Continuous

53

Damper error

5

7

Continuous

57

Intake grille error

5

8

Continuous

58

Indoor unit error

5

15

Continuous

5U

Outdoor PCB/communication error

6

2

Continuous

62

Inverter error

6

3

Continuous

63

Active filter/PFC circuit error

6

4

Continuous

64

Trip terminal ‘L’ error

6

5

Continuous

65

Display PCB/communication error

6

10

Continuous

6A

OU Discharge temp sensor error

7

1

Continuous

71

Compressor temp sensor error

7

2

Continuous

72

OU Heat-Ex liquid temp sensor error

7

3

Continuous

73

OU Ambient temp sensor error

7

4

Continuous

74

OU Suction ref temp sensor error

7

5

Continuous

75

2/3 way valve temp sensor error

7

6

Continuous

76

OU Heat sink temp sensor error

7

7

Continuous

77

Sub-cool inlet/outlet temp sensor error

8

2

Continuous

82

OU Liquid pipe temp sensor error

8

3

Continuous

83

OU current sensor error

8

4

Continuous

84

HP/LP pressure sensor/switch error

8

6

Continuous

86

OU Current trip detection

9

4

Continuous

94

Compressor rotor location detection error

9

5

Continuous

95

OU fan motor error

9

7

Continuous

97

OU fan motor 2 error

9

8

Continuous

98

4-way valve error

9

9

Continuous

99

Coil (expansion valve) error

9

10

Continuous

9A

Outdoor unit error

9

15

Continuous

9U

OU Abnormal discharge temp error

10

1

Continuous

A1

Abnormal compressor temp error

10

3

Continuous

A3

High Pressure error

10

4

Continuous

A4

Low pressure error

10

5

Continuous

A5

VRF Branch box error

13

1

Continuous

J1

8-Way Multi branch box error

13

2

Continuous

J2

Accessories

PCB LED

PCB LED


WRC

VRF RB: Cable crossed OU/RB - IU/RB

on solid

on solid

-

-

VRF RB: Coms/Main PCB error

on solid

Continuous

-

-

WRC: Incompatible IU connected

-

-

-

C0:15

WRC: Indoor - WRC comms error

-

-

-

C0:12


No comments:

Post a Comment