we have 2011 AMERICAN SILVER EAGLE 1 oz. PURE SILVER COIN (UNCIRCULATED) for sale in the UK:
'via Blog this'
In a world where resources are running out it is time to use energy efficient equipment like heat pumps, wind chargers and solar panels to reduce CO2. We are UK specialists in high efficiency air conditioning heat-pumps sales, service and installation. Air Conditioning Heat Pumps have risen to the challenge. We sell all types of high efficiency equipment including brands Fujitsu, LG and Daikin. Our website: www.orionairsales.com
Thursday, 13 December 2012
Tuesday, 11 December 2012
The Queens College Barge Air Conditioning Heat Pump
Installation of Mitsubishi air conditioning heat-pump on the Queens College Barge, Oxford
Orion air conditioning & refrigeration ltd has complete the installation of a Mitsubishi Heavy Industries Air Conditioning Wall air conditioning heat-pump heating system on the Queens College Barge which is now a private house boat for a well known television broadcaster. The wall unit was installed in the bedroom area of the barge which was being heated by low efficiency fan heaters. This type of heating is expensive to run in comparison to heat pumps which can be up to 5 times more efficient.
History of the Queens College Barge, Oxford
The Queens College Barge was a bit of history from the late 19 century with some unique characteristic such as the eagles head on the front. The barge was used for the Queens college rowing team up to the 1960's where it was used as a viewing point for watching the rowing races of the day. Some pictures can be found dating back to the 1890's on race days. It was now moored on a beautiful bank of the river Thames close to Oxford town centre with some amazing views of the river and its wildlife.
What air conditioning heat-pump was installed
1 x Mitsubishi Heavy Industries Air Conditioning SRK28-HG wall mounted (2.8 kW 9000 Btu) Heat pump which provided enough heating for the area at a fraction of the cost of direct electric heaters. The cooling element of the air conditioning unit also makes it useful for summer use when the house boat can get very hot. For more information on heat-pump inverters look here.
For a list of our client have a look at our About Us section
Call: +44(0)845 5677080E-mail: Info@orionair.co.uk
'via Blog this'
Monday, 3 December 2012
Saga Healthcare Server Room Air Conditioning and Humidity control
Server Room Air Conditioning and Humidity control at Saga Healthcare:
'via Blog this'
Orion air conditioning has completed the installation of a replacement server room air conditioning system for Saga Healthcare in Hatfield. The existing mix of cassette and wall mounted air conditioning units were R22 which is now banned for use in the UK and R407c which is banned for use in the UK from 2015. Because the units were old and fixed speed (either on or off according to the thermostat) the efficiency had dropped and the technology had become outmoded. The systems were at the end of their economical and safe life span.
Mitsubishi Electric air conditioning units are renowned for long reliable life span and are ideal for server rooms and Com's rooms were a failure can mean the complete shut down of an entire business or at worst server damage. The new units are energy efficient inverter systems which have a high COP and modulated inverter compressor which can save up to 40% on server room air conditioning that can run 24 hours / 7 days a week.
Pictures of the project:
What air conditioning units were installed at Saga Healthcare:
4 x Mitsubishi Electric Air Conditioning Power Inverter Mr Slim PKA-RP100KAL (10kW / 33000 Btu) which provided enough cooling for the 15 meter square area and 6 server racks in the server room with spare cooling capacity in case of failures. The full replacement of the existing systems with all wall air conditioning units, instead of a mix of cassettes was a safer option because when air conditioning unit fails they tend to leak water. If the water leaks out of a cassette it can drip into the top of important server equipment, with wall units this limits the leakage to the sides of the room. These Mitsubishi PKA-RP100KAL can be found worldwide and have a amazing COP (3.61 x initial electrical input) which means that every 1000w of electrical energy going in produces 3610 watts of cooling.
For more information on air conditioning suitability for server rooms visit our advice page.
Server room air conditioning efficiency and CO2 emissions:
This air conditioning system, because oversized for the area meant we had spare capacity in case of any failure on any of the systems. The clients servers held critical medical data relating patients so could never fail. The bonus of the extra capacity was that the systems ticked over at sub 50% capacity and the outdoor inverter units slowed down because the temperature had been reached, therefore just pumping small amounts of cooling energy in to maintain the server room. The energy saving was phenomenal and CO2 emissions significantly improved.
Why use a Vapac humidifier for your Server room:
The Vapac humidifier is another world renowned product for reliable and safe production of humidity for server rooms, this is ideal when air conditioning is being used as it counter acts the drying affect of air conditioning. The Vapac unit can be controlled by a humidistat which gives you the option of setting the actual humidity percentage for a particular application. For server rooms there are two reasons why you should have humidity control. Firstly ASHRAE’s "Design Considerations for Data and Communications Equipment Centres" recommends relative humidity conditions between 40% and 55%, with an allowable level between 20% and 80%. If a server room has a very low humidity the chance of static can rise to problem levels. Secondly if the server room is habitated by personnel the affect of dry air sub 20% is detrimental to health, skin and eyes.
Power / Heat-Loss Summery:
Server room efficiency: 85% approximately Total power of servers: 20000 Watts Total heat loss: 2550 Watts@85% Room in Square Meters: 18750 Watts Total Heat Load: 21300 WattsKey points to think about when getting air conditioning for server rooms:
- Use inverter air conditioning as it will save energy in the long run.
- Always follow the ASHRAE’s Design considerations for data and communications equipment centres guidelines towards humidity
- Cheap air conditioning units do not work in cold weather because they do not have a outside fan speed controller (low ambient kit)
- Use a established brand so if a part fails on you Server room air conditioning you are not waiting 8 weeks for a spare part.
- Sometimes it is worth having two server room air conditioning units because if one fails you still have some cooling.
- To establish the heat load of you servers add up all the power supplies of your servers rack and assume a 40% loss to heat. i.e- If you have 10 servers with 400watt power supply the total watts will be 4000 watts. assuming a 40% loss the heat load will be 1600 watts.
- Work on a average watts per/Msq of 125watts, so if you server room is 5 x 5 meters you will require a base of 3.5kw/12000btu + the heat load.
- Advised manufactures for server room air conditioning Mitsubishi, Daikin, Fujitsu and Lg
- Always use auto-restart units for server room air conditioning units as power failures can shut budget air conditioning down.
- If your server room is temporary (ie short term lease on building) or has building restrictions then portable air conditioning maybe your only option.
- If using portable air conditioning for your server room then make sure it recycles the water for better cooling performance of that it has a integral condensate pump.
- Use a established business who will not be going out of business for your server room air conditioning installation as the warranty of the air conditioning is with the supplier not the manufacturer.
We offer a complete service to IT Managers, Building Managers and Server Room / Computer / COMS room managers. Call us for a comprehensive quotation on varied air conditioning manufactures to suit any budget on new installations. We have worked with many Blue-chip organisations in helping them develop their server room air conditioning.
| Contact Us:Call: +44(0)845 567 7080 for details on server room humidification and air conditioning quotations. We offer a international supply and installation service. E-mail: info@orionair.co.uk |