Sinclair Air Conditioning ASH-24AIE (7KW / 24000Btu) Wall Mounted Inverter Heat Pump​



Designed for comfort cooling and heating the ASH models have a attractive indoor unit and new design air inlet. The Sinclair wall units provide easier cleaning as the air return is at the top and the front fascia has no air inlet. The unit is a slim line construction only 214mm deep.
The high density heat exchanger on the indoor unit optimizes and enhances the flow/K calories ratio and produces very little noise (37dB@1meter). Because of high quality design the turbine fans are able to work at lower revolutions and minimizes the noise thanks to its greater diameter.
The outdoor inverter unit is made from light material, are smaller and more efficient as it uses the latest Japanese inverter compressor technology. Among the many qualities of ASH models is the noise reduction as a result of the absorption of vibrations and the incorporation of unique details, such as the protection of the connection valves.

Key Product Features:

• Energy class A/A
• Powerful Japanese compressor technology
• 3-year warranty
• R410a environmentally friendly refrigerant
• Dual side water outlet
• Small size
• Comfortable sleep mode
• Standard filters-catechin and active carbon filter
• High speed digital signal processor


Specification:
 
MODELASH-24AIE
Capacity cooling / heatingkW6,5(2,5-6,6) / 7,0(2,5-7,6)
Power supplyHz/V1~ / 50 / 220-240
UnitIndoor
Power input cooling / heatingW2180 / 2220
Rated power input cooling / heatingW2650 / 2800
Power current cooling / heatingA9,7 / 10,5
SEER / SCOPW/W5,10 / 3,80
Energy class-A / A
Air flow IDm³/h1000 / 800 / 700 / 550
Sound pressure level IDdB(A)51 / 47 / 42 / 37
Sound pressure level ODdB(A)58
Air flow ODm³/h4000
Dehumidifying  volumel/h2,0
Refrigerant type / chargeType / kgR410A / 1,8
Pipe diameterLiquid sideinch / mm¼ / 6,4
Gas sideinch / mmǫ / 15,9
Standard pipe lengthm5,0
Max. pipe lengthm25,0
Elevation / Drop heightMaxm10,0
Additional refrigerantg/m50,0
Dimension (w x h x d) ID / ODmm1008x319x221
mm980x790x427
Net weight ID / ODkg14,5 / 55,5
Operating temperature rangeCooling°C18 ~ 43
Heating°C-7 ~ 24
 
 


Thursday, 17 February 2011

Dura 7 + Swimming Pool Air Heat Pump Heater (7 kw / 24000 Btu) Low Operating Temperature

www.orionairsales.co.uk

Dura 7 + Swimming Pool Air Heat Pump Heater (7 kw / 24000 Btu)

DURATECH® heat pumps utilize the sun’s free heat by collecting and absorbing energy from the outside air. This energy is then transferred to the pool water. Your existing pool pump circulates the water through the heater and warms the pool. The unit contains a fan that draws in outside air and directs it over the surface of the EVAPORATOR (energy collector). The liquid refrigerant within the EVAPORATOR coil absorbs the heat from the outside air and the refrigerant becomes a gas. The warm gas passes through the compressor where it is compressed to form a very hot gas, which then passes through the CONDENSOR (water heat exchanger). It is here that the heat exchange occurs as the hot gas gives up the heat to the cooler swimming pool water circulating through the coil. The pool water becomes warmer and the hot gas is cooling down as it flows through the CONDENSOR coil, returns to its liquid form and, after passing through the expansion valve, the whole process begins again. The use of a highly efficient, low sound rotary or scroll compressor, a low noise fan and an oversized heat exchanger, makes the unit to be extremely quiet in operation. Example: the DURA 8 at 10m distance gives only 32 db(A). The Dura range comes in two formats the standard and Dura+ range, the key differences being the Dura+ range will work down to a lower outside temperature -10*c and have a higher COP range over their operating temperature.

Key Product Feature's:

# Model: Dura 7+ (Output 7KW)
# Works down to outside air temperature -10*c
# Maximum pool volume 30 m3
# COP @ air temperature 25*c = 5.8
# Volts 220-240V single phase
# Maximum input current 6.5 amps
# Noise level 50db
# Refrigerant R410A
# Nominal water flow m3/h = 3
# Water connections 50mm
# Dimensions: L905, W420, H650
# Weight 55Kg



The unit is intelligently designed and remarkably compact for easy installation. The heat pump has to be installed on a by-pass after the filtration pump.

www.orionairsales.co.uk : The unit is intelligently designed and remarkably compact for easy installation. The heat pump has to be installed on a by-pass after the filtration pump.

The integrated microprocessor monitors all the sensors and controls the device without any intervention of the user. Electronic display and control with easy operation is standard. The integrated flow switch will sense the water flow and automatically start the heater when the pool pump starts and stops when the pump shuts off.

www.orionairsales.co.uk: The integrated microprocessor monitors all the sensors and controls the device without any intervention of the user.