In a world where resources are running out it is time to use energy efficient equipment like heat pumps, wind chargers and solar panels to reduce CO2. We are UK specialists in high efficiency air conditioning heat-pumps sales, service and installation. Air Conditioning Heat Pumps have risen to the challenge. We sell all types of high efficiency equipment including brands Fujitsu, LG and Daikin. Our website: www.orionairsales.com
Friday, 18 February 2011
Super Energy Efficiency Heat Pump Hitachi Summit Wall Air Conditioning RAS-25FH6 (2.5 kW / 9000 btu) Inverter
The New Hitachi Summit range is highly economical and environmentally friendly, using the latest compressor and inverter technology keeping power consumption minimal, but at the same time providing you with powerfull cooling and heating. High COP
Performance Improved
DC Inverter driven compressors and fans. Enhanced inverter performance and system performance are achieved by the addition of a ‘Direct Current’ drive, resulting in up to 10% more efficient than standard 'AC' (Alernating Current) Systems.
The variable speed compressor(inverter) enables the system to rapidly reach the desired room temperature setting. Once the desired room temperature has been achieved the compressor rotation speed is reduced, saving up to 30% in energy usage (when compared to standard fixed speed systems)
Product Key Feature's
* High CoP, up to record 4.31
* Infra-red controller
* Slim construction 205mm
* Pipe runs up to 20 meters
* Low noise 44dBA on low
* Cold draft prevention on heat pump start up
* Fault diagnosis
* Auto re-start after power interruption
* PRE-CHARGED WITH REFRIGERANT for up to 20 metres pipe length
* Cleaner and healthier air with ion generator incorporated in indoor unit.
* Light weight noise absorbing outdoor unit
RAS Wall Mounted RAS-18FH6
Power source 1 ph 240V
Type Inverter rotary
COOLING (nominal) max. kW 2.0 / 6600 BTU
HEATING (nominal) max. kW 2.5 / 8250 BTU
UK Cooling (max) kW 2.5 / 8250 BTU
UK Heating (max) kW 3.2 / BTU 10600
Fuse Rating 16A
E.E.R. n/a
Energy label in heating A
Energy label in cooling A
C.o.P 4.31
ECA - Yes
Indoor Unit
Exterior dimensions (mm) 280 x 780 x 205
Net weight kg 9.5
Air flow rate* (cooling) (m3//min) 7.3/6.7/5.8
Air flow rate* (heating) (m3//min) 8.0/7.0/5.8
Hitachi Summit, Hitachi air conditioning, Hitachi air conditioning RAS range
Outdoor Unit
Exterior dimensions (mm) 548 x 750 x 288
Net weight kg 35
Power Source Rating MCB A 15A
Refrigerant max piping length m 20
Pipe sizes - 1/4" x 3/8"
Hitachi Summit, Hitachi air conditioning, Hitachi air conditioning RAS range
Thursday, 3 February 2011
Mitsubishi Electric Hyper Inverter Heat Pump MSZ-FD25 Wall Mounted (2.5kW / 9000Btu) High COP Inverter Air Conditioning
The most efficient Mitsubishi Electric air conditioning unit on the market (5.33 x input) or (5250 watts for 984 watt input)
2 day delivery at www.orionairsales,com
The MSZ-FD Series is our most efficient M Series wall mounted unit to date. These high COP models feature the new Plasma Duo filter system. These models also offer industry leading noise levels and has a distinctively styled front panel that not only looks appealing but also helps make the cleaning of the unit easier. Also incorporated is an I-See Sensor, providing even temperature distribution and further reducing energy consumption. |
This model has been completely redesigned and features the new Catechin filter system. It offers industry leading noise levels and has a distinctively styled front panel that not only looks appealing but also helps make the cleaning of the unit easier. Designed to heat or cool small to medium sized applications, the M Series rangeprovides a versatile, yet affordable air conditioning solution. Quick to install and also one of the quietest units on the market (as low as 21dBA* 1 ), this newly designed, attractive range offers the perfect way to ensure a comfortable environment with the minimum of disruption. Unlike conventional models with a grilled air intake, wall mounted models feature a smoothly contoured, flat panel finish with a top air intake that not only improves aesthetics, but also helps to reduce noise as the heat exchanger area is fully covered. This is as a result of the multi-angled heat exchanger having a modified fin shape that reduces air resistance, producing a smoother, quieter flow of air. Alongside this, the wide diameter of the fan produces greater airflow at lower fan speeds and the uneven pitch between each fan blade helps to eliminate unwanted noise. |
Key Product Feature's
• High CoP, up to record 5.33
• Advanced technology control
• Infra-red controller
• Slim construction
• Pipe runs up to 20 metres
• Low noise – 21dBA on smaller models
• Fault diagnosis
• Auto re-start after power interruption
• PRE-CHARGED WITH REFRIGERANT for
up to 7 metres pipe length
• Easy cleaned & serviced.
• Full ECA tax allowance.
Indoor Unit Data
| Capacity (kW): | |
| Heating (Nominal) (Low - High) | 3.20 (1.50 - 6.30) |
| Cooling (Nominal) (Low - High) | 2.50 (1.10 - 3.50) |
| Heating (UK) (Low - High) | 2.65 (1.25 - 5.25) |
| Cooling (UK) (Low - High) | 2.50 (1.10 - 3.45) |
| SHF R410A (Nominal) | 0.85 |
| COP / EER (Nominal) | 5.33 / 5.15 |
| Energy Label Heating / Cooling | A / A |
| Width - mm | 798 |
| Depth - mm | 257 |
| Height - mm | 295 |
| Weight - kg | 12 |
| Airflow (m3/min) (Heating /Cooling) - Lo-Mi1-Mi2-Hi | 4.5-6.7-9.2-12.1 /4.6-6.3-8.6-11.2 |
| Noise (dBA) (Heating /Cooling) - Lo-Mi1-Mi2-Hi | 20-29-36-43 /20-29-36-42 |
| Pipe Size Gas mm (in) | 9.52 (3/8) |
| Pipe Size Liquid mm (in) | 6.35 (1/4) |
| Electrical Supply | Fed by Outdoor Unit |
| Phase | Single |
| Fuse Rating (BS88) - HRC (A) | 6 |
| Interconnecting Cable No. Cores | 4 |
Outdoor unit
| Width - mm | 800 |
| Depth - mm | 285 |
| Height - mm | 550 |
| Weight - kg | 36 |
| Noise (dBA) (Heating /Cooling) | 46 /46 |
| Electrical Supply | 220-240v, 50Hz |
| Phase | Single |
| Fuse Rating (BS88) - HRC (A) | 10 |
| SystemPower Input (kW) - Heating (Nominal) | 0.6 |
| SystemPower Input (kW) - Cooling (Nominal) | 0.485 |
| SystemPower Input (kW) - Heating (UK) | 0.546 |
| SystemPower Input (kW) - Cooling (UK) | 0.388 |
| SystemRunning Current (A) - Heating / Cooling | 2.9 / 2.4 |
| Mains Cable No. Cores | 3 |
| Max Pipe Length (m) | 20 |
| Max Height Difference (m) | 12 |
| Charge (kg) - 7m | 1.15 |