RAC MULTISPLIT FAULT CODES - Historic Models
|
|||||
Inverter Multi Indoor
|
SKM
|
ZD, ZF, ZG
|
|||
SRRM
|
ZE, ZF
|
||||
ST M
|
ZE, ZF
|
||||
Inverter Multi
Outdoor
|
SCM
|
ZD-S, ZF-S, ZG-S
|
|||
Indoor Unit Display
|
Outdoor Control PCB,
Red LED
|
Wired
Remote Control
|
Description of Trouble
|
Possible Cause
|
|
Run Light
Green
|
Timer Light
Amber
|
||||
-
|
-
|
-
|
E1
|
Error of wired remote
|
Broken wire, faulty indoor
P.C.B., faulty
controller.
|
1x
|
ON
|
OFF
|
E6
|
Indoor heat exchanger sensor
(1)
|
Broken heat exchanger sensor
(1) wire, poor
connection
|
2x
|
ON
|
OFF
|
E7
|
Room temperature sensor
|
Broken room temperature sensor wire, poor
connection
|
2x
|
2x
|
7x
|
E60
|
Rotor lock
|
Faulty compressor, open phase on
compressor, faulty outdoor P.C.B.
|
4x
|
ON
|
OFF
|
E9
|
Drain error
|
Blocked drain, faulty float switch, faulty drain
pump
|
5x
|
ON
|
OFF
|
E6
|
Indoor heat exchanger sensor
(2)
|
Broken heat exchanger sensor
(2) wire, poor
connection
|
6x
|
ON
|
OFF
|
E16
|
Indoor fan motor error
|
Fault indoor fan motor, poor connection
|
7x
|
ON
|
OFF
|
E6
|
Closed serv ice
v alv e, indoor heat exchanger sensor (1)
|
Closed serv ice v alv e, indoor
heat exchanger disconnected or open circuit
|
Flashing
|
1x
|
Flashing
|
E38
|
Outdoor air temperature sensor
|
Broken sensor wire, poor
connection
|
Flashing
|
2x
|
Flashing
|
E37
|
Outdoor heat exchanger sensor
|
Broken sensor wire, poor
connection
|
Flashing
|
4x
|
4 sec on/off
|
E39
|
Discharge pipe sensor
|
Broken sensor wire, poor
connection
|
Flashing
|
5x
|
Flashing
|
E53
|
Compressor suction sensor
|
Broken sensor wire, poor
connection
|
Flashing
|
6x
|
Flashing
|
E41
|
Power transistor sensor error
|
Broken sensor wire, poor
connection
|
ON
|
1x
|
1x
|
E42
|
Current Cut
|
Compre s s or l ocki ng, ope n pha s e on compre s s or output, s hort ci rcui t on powe r tra ns i s tor, cl os e
d s e rvi ce va l ve
|
ON
|
2x
|
2x
|
E59
|
Trouble of outdoor unit
|
Broken compressor wire, broken power
transistor, broken discharge sensor wire
or
|
ON
|
3x
|
3x
|
E58
|
Current safe stop
|
Ov
erload protection, ov er charged,
compressor
locking
|
ON
|
4x
|
4x
|
E41
|
Power transistor error
|
Broken power transistor
|
ON
|
5x
|
5x
|
E36
|
Ov er heat of compressor
|
Low on gas, faulty discharge pipe
senor,
closed serv ice v alv e
|
ON
|
6x
|
6x
|
E5
|
Error or signal transmission
|
Defectiv e power supply, broken signal wire, faulty indoor/outdoor P.C.B.
|
ON
|
7x
|
ON
|
E48
|
Faulty outdoor fan motor
|
Faulty condenser fan motor, poor connection
|
Technical Sales And Spares
Tel: +44 (0)845 567
70 80
Fax: +44 (0)1234
780148
e-mail: info@orionair.co.uk
Skype: orionairsales
Orion Air
Conditioning & Refrigeration Ltd
10 Grisedale Court,
Woburn Road Ind.
Est.
Kempston,
Bedfordshire,
MK42 7EE,
United Kingdom
No comments:
Post a Comment