Thursday 20 December 2018

Mitsubishi Heavy Industries Air Conditioning Fault Codes For PAC Multi Indoor and Outdoor systems HEN, HENR, HENAR, VN, VNP, VS, VSA, VNX,VSX






PAC SELF-DIAGNOSIS INFORMATION
Inverter PAC
Outdoor
FDCVA
HEN, HENR, HENAR
FDC
VN, VNP, VS, VSA, VNX,VSX
Error Code
Indoor PCB LEDs
Outdoor unit LEDs
Description of Fault
Possible Cause
RED
GREEN (1)
RED
GREEN (1)
INV LED

E33

Off

Flashing

1x

Flashing

-

Power supply

Anomalous current on inv erter primary side

E34

Off

Flashing

1x

Flashing

Flashing

Power supply
Phase open circuit, faulty outdoor control PCB (3 Phase model)

E35

Off

Flashing

1x

Flashing

Flashing
Outdoor heat exchanger thermistor
Ov erheat of condenser, faulty thermistor, faulty outdoor PCB

E36

Off

Flashing

1x

Flashing

Flashing

Discharge pipe thermistor
High discharge temp, faulty sensor, faulty outdoor control PCB

E37

Off

Flashing

1x

Flashing

Flashing
Outdoor heat exchanger thermistor
Poor connection, broken wire, faulty thermistor, faulty PCB

E38

Off

Flashing

1x

Flashing

Flashing

Outdoor ambient air sensor
Poor connection, broken wire, faulty thermistor, faulty PCB

E39

Off

Flashing

1x

Flashing

Flashing

Discharge pipe thermistor
Poor connection, broken wire, faulty thermistor, faulty PCB

E40

Off

Flashing

1x

Flashing

Flashing

High Pressure Error
Activ ation of HP switch (63H1), closed serv ice v alv e, faulty PCB (63H1 Circuit)

E41

Off

Flashing

1x

Flashing

2 or 6x

Power Transistor ov erheat

S hort circuit of air flow, faulty Inv erter PCB

E42

Off

Flashing

1x

Flashing

1 or 5x

Current Cut
Closed serv ice v alv e, faulty outdoor control PCB

E45

Off

Flashing

1x

Flashing

Flashing
Communication      Error      - Inv erter to Control PCB
Poor Connection, faulty control or inv erter PCBs

E47

Off

Flashing

1x

Flashing

7x
Control PCB, Power transistor

Anomalous inv erter ov er v oltage

E48

Off

Flashing

1x

Flashing

Flashing

Condenser fan motor

Faulty fan motor or outdoor PCB

E49

Off

Flashing

1x

Flashing

Flashing

Low Pressure Error
Closed serv ice v alv e, short of gas, faulty LP sensor, faulty outdoor control PCB

E51

Off

Flashing

1x

Flashing

2 or 6x

Inv erter Error

Faulty Inv erter PCB

E53

Off

Flashing

1x

Flashing

Flashing

S uction pipe thermistor
Poor connection, broken wire, faulty thermistor, faulty PCB

E54

Off

Flashing

1x

Flashing

Flashing

Low Pressure S ensor Error
Closed serv ice v alv e, short of gas, faulty LP sensor, faulty outdoor control PCB

E55

Off

Flashing

1x

Flashing

Flashing
Under-dome temp thermistor
Poor connection, broken wire, faulty thermistor, faulty PCB

E57

Off

Flashing

1x

Flashing

Flashing

Low Pressure Error

Insufficient refrigerant

E59

Off

Flashing

5x

Flashing

Off or 4x

Compressor start up error

Faulty power supply, faulty inv erter circuit.

E60

Off

Flashing

1x

Flashing

-

Compressor

Faulty compressor, faulty inv erter circuit.

E75

Off

Flashing

Off

Flashing

-
Central Controller communication error
Poor connection, broken wire, faulty controller




Technical Sales And Spares


Tel: +44 (0)845 567 70 80

Fax: +44 (0)1234 780148



Skype: orionairsales
Orion Air Conditioning & Refrigeration Ltd
10 Grisedale Court,
Woburn Road Ind. Est.
Kempston,
Bedfordshire,
MK42 7EE,
United Kingdom

No comments:

Post a Comment