Showing posts with label Pumps. Show all posts
Showing posts with label Pumps. Show all posts

Monday, 3 December 2018

JetFlow limpet 5A Dosing PCB Controller For Peristaltic And Flow Pumps 110V~60Hz/240V~50Hz
















Designed for hydroponics and aquatic dosing, pump and water pump control.


This Kit Includes:

1 x Limpet 5A Dosing PCB
2 x Aspen Standard Peristaltic Pumps
1 x Standard Solenoid Water Inlet 15mm




The JetFlow Limpet 5A is a multi-functional output controller that lets the user control dosing quantities to a given liquid, this can be for PH and TD control. The Limpet has two outputs, one for the control of the main liquid flow to be dosed (via solenoid valve or pump) and the other the dosing component. The outputs are mains voltage so the user can control pumps or solenoid valves to allow optimum controlled dosing. The Limpet works on simple principles, there are two inputs for a low and high liquid level input, i.e float switches and a controller timer which controls a dosing component. The user works out the volume of liquid between their two float switches and then works out the required dosing component amounts required for that volume of liquid. The timer is then set to control the flow of the dosing component based on the flow rate of the dosing pump. Multi use applications include aquatics, farming, hydroponics and industry used as a mains-powered monitor or, by adding a solenoid valve or peristaltic pump.




Example of working out dosing levels: 


Volume of liquid requiring dosing (DV): 100 Litres
Dosing Pump Litres/Sec (DP): 1.5 ml/sec
Required dosing per Litre in ml (RD): 1


DV / RD = 100 ml (100 Litres/1) = 100 ml
100ml / DP = 66.6 Seconds

 
Technical Data:



Brand: Jetflow
Switching Amps: 5
Outputs: 2, 1 timed and 1 for level control
Weight (kg): 0.256 Kg
Voltage: 110-220-240V 50/60Hz
Power Consumption: 10W
Dimensions: 138 x 83 x 88mm

Power Cable Length (m): 1.5m approx


View the full product:



JetFlow ,Limpet, 5A ,Dosing PCB, Controller, Peristaltic, Flow, Pumps, 110v~60Hz, 240V~50Hz, hydroponic, hydroponics, Aquatic, dosing, 

Friday, 18 March 2011

Heat pumps are bringing benefits to our Commercial buildings

With the excitement being created by rapidly growing application of heat pumps in the residential sector to replace conventional central heating boilers, it is often mistakenly thought that this is a recent innovation, this is not the case; heat pumps have been with us for over 50 years, indeed they are a dominant feature in the commercial buildings sector.


What we are seeing in the residential sector is the emergence of air or ground source-to-water heat pumps, which can satisfy space heating and domestic hot water requirements utilising conventional heat emitters - radiators, fan coil units or underfloor heating and hot water storage cylinders. Heat Pumps being part renewable, part electric technology, achieve far greater operating efficiencies than all electric or fossil fuel (gas or oil), combustion based boilers. Heat pumps have been recognised as being capable of helping us reach our carbon emission reduction targets not to mention greatly reducing our household heating bills.

In the commercial sector the pre-eminent heat pump is the air source air-to-air type, which can satisfy the space heating and cooling requirements, however, the sanitary hot water services are still mainly provided by secondary systems such as all electric or gas/oil fired boilers.

Pre 1990's most commercial buildings were cooled by air or water-cooled chillers circulating chilled water to wall mounted or ducted fan coil units and heated by conventional 'wet' central heating systems, either utilising the same fan coil units or radiators. In the mid 1980's, Daikin Industries developed an ingenious new heat pump technology called Variable Refrigerant Volume or VRV. This revolutionised the commercial air conditioning market because, for the first time there was a single system that could efficiently cool and heat commercial buildings, reducing dependence on energy guzzling boilers, which would now only be needed, in smaller capacities, for providing hot water.

What's more, VRV could offer simultaneous cooling and heating from the same system by re-distributing waste or rejected heat that would otherwise discharged to atmosphere! VRV offered many other benefits apart from superior energy efficiency, it was a modular concept so proved much more flexible in terms of the space it occupied and in programming the installation works.


Daikin Air Heat Pumps












Electrical loads were reduced and the speed with which VRV was able to respond to demand was far quicker than any chilled water/secondary heating system.
No surprise then that modular VRV (and later derivatives known as VRF) overtook central chiller systems in terms of popularity in the commercial sector.

However, certain commercial applications remain better suited to chiller systems, for example in large areas with a single temperature set-point or where response times are less critical, spaces with larger cooling loads or very high ceilings.

So has chiller development learned any lessons from the success of VRV? - Heat pump chillers have also been available for some years but at a premium that hindered their success. Such chillers could only operate in cooling or heating. In heating mode, there were limitations and in certain conditions a secondary heating source would still be required to satisfy the heating demand. This has been largely resolved with the more recent introduction of inverter technology (which VRV/VRF had adopted years earlier). Inverter technology enables the heat pump chiller's compressor/s to be boosted, in more extreme conditions, with a frequency increase that exactly follows the required thermal load, resulting in a wider operating range and reducing or eliminating the need for secondary heating.

Heat recovery, heat pump chillers manage to get a little closer to VRV/VRF capabilities because, the chillers offer cooling and heating as before - but - in cooling mode, heat absorbed from the conditioned space and from the compressors, instead of being rejected to atmosphere, is recovered and directed to a second heat exchanger. The recovered heat energy can then be used in areas calling for heating or passed to a thermal storage facility for hot water. In this way chillers can offer simultaneous heating and cooling, a common requirement in commercial buildings, at remarkably high efficiencies.

To manage the heating and cooling requirements of our commercial buildings it's not so much a question of why install heat pumps rather than other technology? More the fact that no other systems offer anything like equivalent energy efficiency and cost effectiveness. A fact that we in the industry trust will be acknowledged in the government's soon to be announced Renewable Heat Incentive.